Slip-on geared motor Compacta MR30
Dimensions for standard drive
| |
Standard:
|
- 3-phase AC motor
- Terminal box
- Hollow shaft
- Any transmission
- Thermal protection
- IP 54
- Plastic 1st gear stage
|
Options
| |
 |
| Options with dimensions [mm] |
a |
b |
| Single phase AC motor |
(-) |
(-) |
| DC motor |
(-) |
239 |
| Motor disc brake |
(-) |
244 |
| Hand crank |
(-) |
380 |
| Limit switch version 1 / 2P |
218 |
(-) |
(-) Does not affect size
(x) Please refer to the datasheets for any additional or missing dimensions |
3-phase AC motors - 3x230/400V-50Hz
| |
Output speed
n2 min-1 |
Output torque
Nm
duty cycle 60% |
Transmission
ratio |
Motor speed
n1 min-1 |
Motor output
kW
duty cycle 60% |
Self
locking |
Max. limit switch range
Output rotation * |
normal |
long |
| 123,4 |
60 |
22,7:1 |
2800 |
1,1 |
So |
260 |
430 |
| 61,6 |
112 |
45,4:1 |
2800 |
1,1 |
So |
130 |
215 |
| 39 |
165 |
71,8:1 |
2800 |
1,1 |
So |
85 |
135 |
| 30,8 |
125 |
45,4:1 |
1400 |
0,6 |
So |
130 |
215 |
| 28,4 |
187 |
98,3:1 |
2800 |
1,1 |
So |
60 |
100 |
| 21,8 |
220 |
128,5:1 |
2800 |
1,1 |
Ss |
47 |
77 |
| 19,5 |
180 |
71,8:1 |
1400 |
0,6 |
So |
85 |
135 |
| 15,4 |
240 |
181,4:1 |
2800 |
1,1 |
Ss |
32 |
55 |
| 14,2 |
206 |
98,3:1 |
1400 |
0,6 |
So |
60 |
100 |
| 11,8 |
270 |
238,1:1 |
2800 |
1,1 |
Sd |
25 |
42 |
| 10,6 |
250 |
264,6:1 |
2800 |
1,1 |
Sd |
23 |
38 |
| 7,7 |
267 |
181,4:1 |
1400 |
0,6 |
Ss |
32 |
55 |
| 5,9 |
300 |
238,1:1 |
1400 |
0,6 |
Sd |
25 |
42 |
| 5,3 |
278 |
264,6:1 |
1400 |
0,6 |
Sd |
23 |
38 |
| 3,8 |
148 (40% d.c.) |
181,4:1 |
700 |
0,23 (40% d.c.) |
Ss |
32 |
55 |
| 2,9 |
170 (40% d.c.) |
238,1:1 |
700 |
0,23 (40% d.c.) |
Sd |
25 |
42 |
| 2,6 |
160 (40% d.c.) |
264,6:1 |
700 |
0,23 (40% d.c.) |
Sd |
23 |
38 |
So = no self locking; Ss = static self locking; Sd= dynamic self locking
**At 100% relative duty (continuous duty), cooling is always required.
With cooling. motors rated at 60%, 100% duty operation can be achieved.
|
Single phase AC motors - 1x230V-50Hz
| |
Output speed
n2 min-1 |
Output torque
Nm (40% duty cycle) ** |
Transmission
ratio |
Motor speed
n1 min-1 |
Motor output
kW |
Self
locking |
| 123,4 |
36,0 |
22,7:1 |
2800 |
0,66 |
So |
| 61,6 |
67,2 |
45,4:1 |
2800 |
0,66 |
So |
| 39 |
99,0 |
71,8:1 |
2800 |
0,66 |
So |
| 30,8 |
73,3 |
45,4:1 |
1400 |
0,36 |
So |
| 28,4 |
112,2 |
98,3:1 |
2800 |
0,66 |
So |
| 21,8 |
132,0 |
128,5:1 |
2800 |
0,66 |
Ss |
| 19,5 |
108,0 |
71,8:1 |
1400 |
0,36 |
So |
| 15,4 |
144,0 |
181,4:1 |
2800 |
0,66 |
Ss |
| 14,1 |
122,3 |
98,3:1 |
1400 |
0,36 |
So |
| 11,8 |
162,0 |
238,1:1 |
2800 |
0,66 |
Sd |
| 10,9 |
144,0 |
128,5:1 |
1400 |
0,36 |
Ss |
| 10,6 |
150,0 |
264,6:1 |
2800 |
0,66 |
Sd |
| 7,7 |
157,1 |
181,4:1 |
1400 |
0,36 |
Ss |
| 5,9 |
176,7 |
238,1:1 |
1400 |
0,36 |
Sd |
| 5,3 |
163,4 |
264,6:1 |
1400 |
0,36 |
Sd |
So = no self locking; Ss = static self locking; Sd= dynamic self locking
** The stated single phase torques are operational torques. The starting torque may be only 66% of the stated catalog torque. Please contact the manufacturer if max. torque is required.
|
24V DC shunt wound motor
| |
Output speed
n2 min-1 |
Output torque
Nm |
Self locking |
Transmission
ratio |
| 66 |
52 |
So |
22,7:1 |
| 33 |
97 |
So |
45,4:1 |
| 21 |
141 |
So |
71,8:1 |
| 15 |
162 |
So |
98,3:1 |
| 11,5 |
190 |
Ss |
128,5:1 |
| 8 |
205 |
Ss |
181,4:1 |
| 6,5 |
220 |
Sd |
238,1:1 |
| 5,5 |
200 |
Sd |
264,6:1 |
So = no self locking; Ss = static self locking; Sd= dynamic self locking
P = 0,5 kW
IN = 30A
40% duty cycle
The output speed of Compacta gear motors with DC motors varies with the output torque.
The gear motor can be overloaded by 50% for brief periods. Single-phase AC and DC motors may stall. |
Download Technical Documentation (PDF-files)
Please contact the manufacturer regarding the following operating conditions:
• Temperatures below 0°C (single phase AC and DC motors: below 10°C)
• Temperatures above 40°C
• Strong vibrations
|