HOME
DOWNLOADS
TRADE FAIR
PRESS
CAREER

  Award for "Supplier of the year 2009" of 3M Espe  
  Read more...
  New Sales Manager  
  Read more...
  New Corporate Design  
  Read more...
  MR6    I    MS12    I    MR30    I    AG60    I    Limit switches    I    Inquiry

Slip-on geared motor Compacta MR30

  Options  I  Power table 3-phase AC  I  Power table single phase AC  I  Power table DC

Download Technical Documentation (PDF-files)

Dimensions for standard drive

  Standard:
  • 3-phase AC motor
  • Terminal box
  • Hollow shaft
  • Any transmission
  • Thermal protection
  • IP 54
  • Plastic 1st gear stage
  Compacta slip-on geared motor MR30 Dimensions

 

Options

  Compacta slip-on geared motor MR30 Dimensions of options
Options with dimensions [mm] a b
Single phase AC motor (-) (-)
DC motor (-) 239
Motor disc brake (-) 244
Hand crank (-) 380
Limit switch version 1 / 2P 218 (-)

(-) Does not affect size
(x) Please refer to the datasheets for any additional or missing dimensions

 

3-phase AC motors - 3x230/400V-50Hz

 
Output speed
n2 min-1
Output torque
Nm
duty cycle 60%
Transmission
ratio
Motor speed
n1 min-1
Motor output
kW
duty cycle 60%
Self
locking
Max. limit switch range
Output rotation *

normal

long

123,4 60 22,7:1 2800 1,1 So 260 430
61,6 112 45,4:1 2800 1,1 So 130 215
39 165 71,8:1 2800 1,1 So 85 135
30,8 125 45,4:1 1400 0,6 So 130 215
28,4 187 98,3:1 2800 1,1 So 60 100
21,8 220 128,5:1 2800 1,1 Ss 47 77
19,5 180 71,8:1 1400 0,6 So 85 135
15,4 240 181,4:1 2800 1,1 Ss 32 55
14,2 206 98,3:1 1400 0,6 So 60 100
11,8 270 238,1:1 2800 1,1 Sd 25 42
10,6 250 264,6:1 2800 1,1 Sd 23 38
7,7 267 181,4:1 1400 0,6 Ss 32 55
5,9 300 238,1:1 1400 0,6 Sd 25 42
5,3 278 264,6:1 1400 0,6 Sd 23 38
3,8 148 (40% d.c.) 181,4:1 700 0,23 (40% d.c.) Ss 32 55
2,9 170 (40% d.c.) 238,1:1 700 0,23 (40% d.c.) Sd 25 42
2,6 160 (40% d.c.) 264,6:1 700 0,23 (40% d.c.) Sd 23 38
So = no self locking; Ss = static self locking; Sd= dynamic self locking
**At 100% relative duty (continuous duty), cooling is always required.
With cooling. motors rated at 60%, 100% duty operation can be achieved.

 

Single phase AC motors - 1x230V-50Hz

 
Output speed
n2 min-1
Output torque
Nm (40% duty cycle) **
Transmission
ratio
Motor speed
n1 min-1
Motor output
kW
Self
locking
123,4 36,0 22,7:1 2800 0,66 So
61,6 67,2 45,4:1 2800 0,66 So
39 99,0 71,8:1 2800 0,66 So
30,8 73,3 45,4:1 1400 0,36 So
28,4 112,2 98,3:1 2800 0,66 So
21,8 132,0 128,5:1 2800 0,66 Ss
19,5 108,0 71,8:1 1400 0,36 So
15,4 144,0 181,4:1 2800 0,66 Ss
14,1 122,3 98,3:1 1400 0,36 So
11,8 162,0 238,1:1 2800 0,66 Sd
10,9 144,0 128,5:1 1400 0,36 Ss
10,6 150,0 264,6:1 2800 0,66 Sd
7,7 157,1 181,4:1 1400 0,36 Ss
5,9 176,7 238,1:1 1400 0,36 Sd
5,3 163,4 264,6:1 1400 0,36 Sd
So = no self locking; Ss = static self locking; Sd= dynamic self locking
** The stated single phase torques are operational torques. The starting torque may be only 66% of the stated catalog torque. Please contact the manufacturer if max. torque is required.

 

24V DC shunt wound motor

 
Output speed
n2 min-1
Output torque
Nm
Self locking Transmission
ratio
66 52 So 22,7:1
33 97 So 45,4:1
21 141 So 71,8:1
15 162 So 98,3:1
11,5 190 Ss 128,5:1
8 205 Ss 181,4:1
6,5 220 Sd 238,1:1
5,5 200 Sd 264,6:1
So = no self locking; Ss = static self locking; Sd= dynamic self locking
P = 0,5 kW
IN = 30A
40% duty cycle
The output speed of Compacta gear motors with DC motors varies with the output torque.

The gear motor can be overloaded by 50% for brief periods. Single-phase AC and DC motors may stall.

Download Technical Documentation (PDF-files)

 

Please contact the manufacturer regarding the following operating conditions:
• Temperatures below 0°C (single phase AC and DC motors: below 10°C)
• Temperatures above 40°C
• Strong vibrations