Slip-on geared motor Compacta MR6
Dimensions for standard drive
| |
Standard:
|
- 3-phase AC motor
- Terminal box
- Hollow shaft
- Any transmission
- Thermal protection
- IP 54
|
Options
| |
 |
| Options with dimensions [mm] |
a |
| Single phase AC motor |
(-) |
| DC motor |
200 |
| Motor disc brake |
210 |
| Potentiometer |
(-) |
| Various limit switch versions |
(-) |
(-) Does not affect size
(x) Please refer to the datasheets for additional or missing dimensions
|
3-phase AC motors - 3x230/400V-50Hz
| |
Output speed
n2 min-1 |
Output torque
Nm (30% duty cycle) |
Transmission
ratio |
Motor speed
n1 min-1 |
Motor output
kW |
Self
locking |
Max. limit switch range
Output rotation * |
| 100 |
10,5 |
27:1 |
2700 |
0,22 |
So |
275 |
| 80 |
13 |
34:1 |
2700 |
0,22 |
So |
275 |
| 67 |
15 |
40:1 |
2700 |
0,22 |
So |
184 |
| 54 |
19 |
50:1 |
2700 |
0,22 |
So |
184 |
| 34 |
26 |
80:1 |
2700 |
0,22 |
So |
92 |
| 27 |
33 |
100:1 |
2700 |
0,22 |
So |
92 |
| 17 |
40 |
160:1 |
2700 |
0,22 |
Ss |
46 |
| 14 |
50 |
200:1 |
2700 |
0,22 |
Ss |
46 |
| 12 |
44 |
224:1 |
2700 |
0,22 |
Sd |
33 |
| 10 |
55 |
280:1 |
2700 |
0,22 |
Sd |
33 |
| 8 |
60 (20%ED) |
160:1 |
1300 |
0,15 |
Ss |
46 |
| 6 |
60 (20%ED) |
224:1 |
1300 |
0,15 |
Sd |
33 |
| 4,8 |
60 (20%ED) |
280:1 |
1300 |
0,15 |
Sd |
33 |
| 3,6 |
55 (20%ED) |
360:1 |
1300 |
0,15 |
Sd |
21 |
| 2,9 |
55 (20%ED) |
450:1 |
1300 |
0,15 |
Sd |
21 |
So = no self locking; Ss = static self locking; Sd= dynamic self locking
|
Single phase AC motors - 1x230V-50Hz
| |
Output speed
n2 min-1 |
Output torque
Nm (15% duty cycle)** |
Transmission
ratio |
Motor speed
n1 min-1 |
Motor output
kW |
Self
locking |
| 100 |
6,0 |
27:1 |
2700 |
0,09 |
So |
| 80 |
7,5 |
34:1 |
2700 |
0,09 |
So |
| 67 |
8,5 |
40:1 |
2700 |
0,09 |
So |
| 54 |
10,5 |
50:1 |
2700 |
0,09 |
So |
| 34 |
14,5 |
80:1 |
2700 |
0,09 |
So |
| 27 |
18,0 |
100:1 |
2700 |
0,09 |
So |
| 17 |
21,0 |
160:1 |
2700 |
0,09 |
Ss |
| 14 |
26,5 |
200:1 |
2700 |
0,09 |
Ss |
| 12 |
22,0 |
224:1 |
2700 |
0,09 |
Sd |
| 10 |
27,5 |
280:1 |
2700 |
0,09 |
Sd |
| 8 |
33,5 |
160:1 |
1300 |
0,07 |
Ss |
| 6 |
35,0 |
224:1 |
1300 |
0,07 |
Sd |
| 4,8 |
43,5 |
280:1 |
1300 |
0,07 |
Sd |
| 3,6 |
54,0 |
360:1 |
1300 |
0,07 |
Sd |
| 2,9 |
55,0 |
450:1 |
1300 |
0,07 |
Sd |
So = no self locking; Ss = static self locking; Sd= dynamic self locking
** The stated single phase torques are operational torques. The starting torque may be only 66% of the stated catalog torque. Please contact the manufacturer if max. torque is required.
|
24V DC permanent magnet motor
| |
Output speed
n2 min-1 |
Output torque
Nm |
Self locking |
Transmission
ratio |
| 65 |
7 |
So |
27:1 |
| 51,5 |
8,75 |
So |
34:1 |
| 44 |
10 |
So |
40:1 |
| 35 |
12 |
So |
50:1 |
| 22 |
16,5 |
So |
80:1 |
| 17,5 |
20,5 |
So |
100:1 |
| 11 |
24,5 |
So |
160:1 |
| 9 |
30,5 |
Ss |
200:1 |
| 8 |
25 |
Ss |
224:1 |
| 6 |
31 |
Ss |
280:1 |
| 5 |
38,5 |
Sd |
360:1 |
| 4 |
47,5 |
Sd |
450:1 |
So = no self locking; Ss = static self locking; Sd= dynamic self locking
P = 0,12 kW
IN = 10,5A
20% duty cycle
The output speed of Compacta gear motors with DC motors varies with the output torque.
The gear motor can be overloaded by 50% for brief periods. Single-phase AC and DC motors may stall. |
Download Technical Documentation (PDF-files)
Please contact the manufacturer regarding the following operating conditions:
• Temperatures below 0°C (single phase AC and DC motors: below 10°C)
• Temperatures above 40°C
• Strong vibrations
|