Slip-on geared motor Compacta MS12

  Options  I  Power table 3-phase AC  I  Power table single phase AC  I  Power table DC

Download Technical Documentation (PDF-files)

Dimensions for standard drive

  Standard:
  • 3-phase AC motor
  • Terminal box
  • Hollow shaft
  • Any transmission
  • Thermal protection
  • IP 54
  • Plastic 1st gear stage
  Compacta slip-on geared motor MS12 Dimensions

 

Options

  Compacta slip-on geared motor MS12 Dimensions of options
Options with dimensions [mm] a b
Single phase AC motor (-) (-)
DC motor 286 (-)
DC motor + Motor disc brake 336 (-)
Cone brake 245 (-)
Motor disc brake 295 (-)
Rotor fan 283 (-)
Rotor fan + Motor disc brake 307 (-)
Motor fan (continuos ventilation) 307 (-)
Motor fan + Motor disc brake 333 (-)
Hand crank 382 (-)
Limit switch version 1 / 2P (-) 179
Slipping clutch (x) (x)
Single-ended stub shaft (x) (x)
Bronze 1st gear stage (-) (-)

(-) Does not affect size
(x) Please refer to the datasheets for any additional or missing dimensions

 

3-phase AC motors - 3x230/400V-50Hz

 
Output speed
n2 min-1
Output torque
Nm
Transmission
ratio
Motor speed
n1 min-1
Motor output
kW
Self
locking
Max. limit switch range
Output rotation *
d.c. 40% d.c. 60%
d.c. 100% **
d.c. 40% d.c. 60% 
d.c. 100% **
193 16 12 14,2:1 2750 0,4 0,3 So

275

137,5 21 15,7 20:1 2750 0,4 0,3 So 275
94,8 30 22,5 29:1 2750 0,4 0,3 So 275
68 39,5 29,5 40,5:1 2750 0,4 0,3 So 275
61 44 33 45:1 2750 0,4 0,3 So 275
47,6 45,5 34 29:1 1380 0,3 0,23 So 275
43,6 44 33 63:1 2750 0,4 0,3 So 275
36,7 47 35 75:1 2750 0,4 0,3 So 275
32,7 59 44 84:1 2750 0,4 0,3 Ss 275
30,5 63 47 90:1 2750 0,4 0,3 Ss 275
24,1 72 54 114:1 2750 0,4 0,3 Ss 275
21,9 66 49 63:1 1380 0,3 0,23 So 275
18,3 84 63 150:1 2750 0,4 0,3 Sd 275
16,4 88 66 84:1 1380 0,3 0,23 Ss 275
15,3 94,5 71 90:1 1380 0,3 0,23 Ss 275
12,1 107,5 80,5 114:1 1380 0,3 0,23 Ss 275
9,2 126 94,5 150:1 1380 0,3 0,23 Sd 275
7,7 132 99 180:1 1380 0,3 0,23 Sd 275
6,1 142 106,5 225:1 1380 0,3 0,23 Sd 275
4,5 88 66 (ED 60%) 150:1 680 0,12 0,09 Sd 275
3,8 92 68 (ED 60%) 180:1 680 0,12 0,09 Sd 275
3 100 75 (ED 60%) 225:1 680 0,12 0,09 Sd 275
So = no self locking; Ss = static self locking; Sd= dynamic self locking
**At 100% relative duty (continuous duty), cooling is always required.
With cooling. motors rated at 60%, 100% duty operation can be achieved.

 

Single phase AC motors - 1x230V-50Hz

 
Output speed
n2 min-1
Output torque
Nm (20% duty cycle) ***
Transmission
ratio
Motor speed
n1 min-1
Motor output
kW
Self
locking
193 10,0 14,2:1 2750 0,28 So
137,5 13,0 20:1 2750 0,28 So
94,8 18,0 29:1 2750 0,28 So
68 23,9 40,5:1 2750 0,28 So
61 26,0 45:1 2750 0,28 So
47,6 27,0 29:1 1380 0,25 So
43,6 26,0 63:1 2750 0,28 So
36,7 28,0 75:1 2750 0,28 So
32,7 35,0 84:1 2750 0,28 Ss
30,5 38,0 90:1 2750 0,28 Ss
24,1 43,0 114:1 2750 0,28 Ss
21,9 40,0 63:1 1380 0,25 So
18,3 49,8 150:1 2750 0,28 Sd
16,4 53,0 84:1 1380 0,25 Ss
15,3 56,9 90:1 1380 0,25 Ss
12,1 65,0 114:1 1380 0,25 Ss
9,2 75,9 150:1 1380 0,25 Sd
7,7 79,0 180:1 1380 0,25 Sd
6,1 84,9 225:1 1380 0,25 Sd
So = no self locking; Ss = static self locking; Sd= dynamic self locking
** The stated single phase torques are operational torques. The starting torque may be only 66% of the stated catalog torque. Please contact the manufacturer if max. torque is required.

 

24V DC permanent magnet motor

 
Output speed
n2 min-1
Output torque
Nm
Self locking Transmission
ratio
140 16 So 14,2:1
100 21 So 20:1
69 30 So 29:1
49 40 So 40,5:1
44 45 So 45:1
32 45 So 63:1
27 48 So 75:1
24 60 Ss 84:1
22 65 Ss 90:1
17,5 73 Ss 114:1
13 88 Sd 150:1
11 91 Sd 180:1
8,9 96 Sd 225:1
So = no self locking; Ss = static self locking; Sd= dynamic self locking
P = 0,3 kW
IN = 25A
30% duty cycle
The output speed of Compacta gear motors with DC motors varies with the output torque.

The gear motor can be overloaded by 50% for brief periods. Single-phase AC and DC motors may stall.

Download Technical Documentation (PDF-files)

 

Please contact the manufacturer regarding the following operating conditions:
• Temperatures below 0°C (single phase AC and DC motors: below 10°C)
• Temperatures above 40°C
• Strong vibrations