Home
Downloads
News
Trade Fair
Press
Career
Imprint
|
LiMax 60 I LiMax 80 I Inquiry
Linear actuator LiMax 80
Options I Power tables I Download Technical Documentation (PDF-file)
Standard Version: Three-phase/Single Phase AC, Stroke (200 mm), 1:1, Fixing A
Dimensions marked with * indicate the drive length of a standard drive (i.e. a stroke length of 100mm and a 1-stage or 1:1 transmission ratio). For longer stroke length and/or gear stages please add the corresponding dimensions x and y from the table below.
| Gear |
1:1 |
1-st. |
2-st. |
| x |
0 |
0 |
15 |
|
+ |
| Stroke length |
200 |
400 |
| y |
0 |
200 |
|
|
Fixing D, E, F
| Standard |
Options |
| 200 mm stroke length |
5 mounting versions |
| Mounting version A |
Special stroke length up to 400 mm |
| Thermal protection |
With force-dependent shut off |
| Splash-proof IP65 |
With mounting angles |
| Integrated limit switches |
With encoder |
| Maintenance-free |
With adjustable rod end |
| Lifetime lubrication |
With single disk spring-activated brake |
|
AC 3 x 230 / 400 V - 50 Hz
Motor
speed
[min-1] |
Power
[kW] |
Duty
cycle
[%] |
Planetary
gear |
Trapezoidal
thread
[mm] |
Stroke
speed
[mm/s] |
Maximum stroke force [N]
at stroke length [mm] |
| 200 |
400 |
| 2700 |
0,22 |
30 |
1-st. |
18x8 So |
84 |
1000 |
1000 |
| 2700 |
0,22 |
30 |
1-st. |
18x4 Ss |
42 |
1320 |
1320 |
| 2700 |
0,22 |
30 |
1-st. |
18x3 Sd |
31 |
1400 |
1400 |
| 2700 |
0,22 |
30 |
2-st. |
18x8 So |
19 |
3700 |
3700 |
| 2700 |
0,22 |
30 |
2-st. |
18x4 Ss |
10 |
5000 |
5000 |
| 2700 |
0,22 |
30 |
2-st. |
18x3 Sd |
7 |
5000 |
5000 |
So = no self-locking; Ss = static self-locking; Sd = dynamic self-locking.
1-stage = 4,3:1
2-stage = 18,9:1
Duty cycle applies to 10 min. duty time.
A brake may be required, depending on application.
For tensile loading, the maximum stroke force of the particular stroke speed applies.
|
AC 1 x 230 V - 50 Hz
Motor
speed
[min-1] |
Power
[kW] |
Duty
cycle
[%] |
Planetary
gear |
Trapezoidal
thread
[mm] |
Stroke
speed
[mm/s] |
Maximum stroke force [N]
at stroke length [mm] |
| 200 |
400 |
| 2700 |
0,12 |
15 |
1-st. |
18x8 So |
84 |
540 |
540 |
| 2700 |
0,12 |
15 |
1-st. |
18x4 Ss |
42 |
720 |
720 |
| 2700 |
0,12 |
15 |
1-st. |
18x3 Sd |
31 |
760 |
760 |
| 2700 |
0,12 |
15 |
2-st. |
18x8 So |
19 |
2000 |
2000 |
| 2700 |
0,12 |
15 |
2-st. |
18x4 Ss |
10 |
2700 |
2700 |
| 2700 |
0,12 |
15 |
2-st. |
18x3 Sd |
7 |
2800 |
2800 |
So = no self-locking; Ss = static self-locking; Sd = dynamic self-locking.
1-stage = 4,3:1
2-stage = 18,9:1
Duty cycle applies to 10 min. duty time.
A brake may be required, depending on application.
For tensile loading, the maximum stroke force of the particular stroke speed applies.
|
Technical Documentation
|