Home
Downloads
News
Trade Fair
Press
Career
Imprint
|
Mini 0 I Mini 01 I Mini 1 I Mini 2 I Mini 3 I Inquiry
Linear actuator Mini 0
Options I Power tables I Download Technical Documentation (PDF-file)
Standard Version:
AC, Stroke 100 mm, Transmission Ratio 1-stage or 1-stage, Fixing Version A
Dimensions marked with * indicate the drive length of a standard drive (i.e. a stroke length of 100mm and a 1-stage transmission ratio). For longer stroke length and/or gear stages please add the corresponding dimensions x and y from the table below.
| Gear |
1-st. |
2-st. |
3-st. |
| x |
0 |
12 |
24 |
|
+ |
| Stroke length |
100 |
150 |
200 |
250 |
300 |
| y |
0 |
50 |
100 |
150 |
200 |
|
|
Fixing C
Fixing D, E, F
| Standard |
Options |
| 100 mm stroke length |
DC motor |
| Mounting version A |
4 mounting versions |
| Thermal protection (except DC) |
Special stroke length up to 300 mm |
| Splash-proof IP 54 |
With adjustment ring |
| Integrierte Endabschaltung |
With adjustable rod end |
| Maintenance-free |
With encoder |
| Lifetime lubrication |
With electro-magnetic brake |
| AC motor |
With potentiometer |
| Drive completely in stainless steel |
|
|
AC 1 x 230 V - 50 Hz
Motor
speed
[min-1] |
Motor
power
[kW] |
Duty
cycle
[%] |
Planetary
gear
stages |
Trapezoidal
thread
[mm] |
Stroke
speed
[mm/s] |
Maximum stroke force [N]
at stroke length [mm] |
| 100 |
150 |
200 |
250
300 |
| 1200 |
0,030 |
15 |
1-st. |
10x6 So |
30* |
450 |
450 |
450 |
450 |
| 1200 |
0,030 |
15 |
1-st. |
10x3 Sd |
15 |
600 |
600 |
600 |
600 |
| 1200 |
0,030 |
15 |
1-st. |
10x2 Sd |
10 |
600 |
600 |
600 |
600 |
| 1200 |
0,030 |
15 |
2-st. |
10x6 So |
8 |
1000 |
1000 |
1000 |
600 |
| 1200 |
0,015 |
30-40 |
2-st. |
10x3 Sd |
4 |
1000 |
1000 |
1000 |
600 |
| 1200 |
0,015 |
30-40 |
2-st. |
10x2 Sd |
2,7 |
1000 |
1000 |
1000 |
600 |
| 1200 |
0,015 |
50-60 |
3-st. |
10x6 So |
2 |
1000 |
1000 |
1000 |
600 |
| 1200 |
0,015 |
50-60 |
3-st. |
10x3 Sd |
1 |
1000 |
1000 |
1000 |
600 |
| 1200 |
0,015 |
50-60 |
3-st. |
10x2 Sd |
0,7 |
1000 |
1000 |
1000 |
600 |
So = no self-locking; Ss = static self-locking; Sd = dynamic self-locking
1-stage = 3,9:1
2-stage = 15,2:1
3-stage = 59,3:1
* Brake required.
Duty cycle applies to 10 min. duty time.
For tensile loading, the maximum stroke force of the particular stroke speed applies.
|
DC 24 V DC
Motor
speed
[min-1] |
Motor
power
[kW] |
Duty
cycle
[%] |
Planetary
gear
stages |
Trapezoidal
thread
[mm] |
Stroke
speed
[mm/s] |
Maximum stroke force [N]
at stroke length [mm] |
| 100 |
150 |
200 |
250
300 |
| 1600 |
0,055 |
25 |
1-st. |
10x6 So |
40* |
450 |
450 |
450 |
450 |
| 2000 |
0,055 |
25 |
1-st. |
10x3 Sd |
25* |
600 |
600 |
600 |
600 |
| 2000 |
0,055 |
25 |
1-st. |
10x2 Sd |
16* |
600 |
600 |
600 |
600 |
| 2100 |
0,055 |
25 |
2-st. |
10x6 So |
14* |
900 |
900 |
900 |
600 |
| 2300 |
0,055 |
50 |
2-st. |
10x3 Sd |
7,5 |
1000 |
1000 |
1000 |
600 |
| 2500 |
0,055 |
50 |
2-st. |
10x2 Sd |
5,5 |
1000 |
1000 |
1000 |
600 |
| 2600 |
0,055 |
50 |
3-st. |
10x6 So |
4,5 |
1000 |
1000 |
1000 |
600 |
| 2600 |
0,055 |
50 |
3-st. |
10x3 Sd |
2,2 |
1000 |
1000 |
1000 |
600 |
| 2600 |
0,055 |
50 |
3-st. |
10x2 Sd |
1,5 |
1000 |
1000 |
1000 |
600 |
So = no self-locking; Ss = static self-locking; Sd = dynamic self-locking
1-stage = 3,9:1
2-stage = 15,2:1
3-stage = 59,3:1
* Brake required.
Duty cycle applies to 10 min. duty time.
For tensile loading, the maximum stroke force of the particular stroke speed applies.
|
Technical Documentation
|