Deutsch  I  English  I  Français


Home
Downloads
News
Trade Fair
Press
Career
Imprint



Mini 0    I    Mini 01    I    Mini 1    I    Mini 2    I    Mini 3    I    Inquiry

Linear actuator Mini 0

Options    I    Power tables    I    Download Technical Documentation (PDF-file)

Standard Version:
AC, Stroke 100 mm, Transmission Ratio 1-stage or 1-stage, Fixing Version A



Dimensions marked with * indicate the drive length of a standard drive (i.e. a stroke length of 100mm and a 1-stage transmission ratio). For longer stroke length and/or gear stages please add the corresponding dimensions x and y from the table below.

Gear 1-st. 2-st. 3-st.
x 0 12 24
+
Stroke length 100 150 200 250 300
y 0 50 100 150 200

Fixing C

 

Fixing D, E, F

 

Standard Options
100 mm stroke length DC motor
Mounting version A 4 mounting versions
Thermal protection (except DC) Special stroke length up to 300 mm
Splash-proof IP 54 With adjustment ring
Integrierte Endabschaltung With adjustable rod end
Maintenance-free With encoder
Lifetime lubrication With electro-magnetic brake
AC motor With potentiometer
Drive completely in stainless steel  

 

AC 1 x 230 V - 50 Hz

Motor
speed
 
[min-1]
Motor
power
 
[kW]
Duty
cycle
 
[%]
Planetary
gear
stages
Trapezoidal
thread
 
[mm]
Stroke
speed
 
[mm/s]
Maximum stroke force [N]
at stroke length [mm]
100 150 200 250
300
1200 0,030 15 1-st. 10x6 So 30* 450 450 450 450
1200 0,030 15 1-st. 10x3 Sd 15 600 600 600 600
1200 0,030 15 1-st. 10x2 Sd 10 600 600 600 600
1200 0,030 15 2-st. 10x6 So 8 1000 1000 1000 600
1200 0,015 30-40 2-st. 10x3 Sd 4 1000 1000 1000 600
1200 0,015 30-40 2-st. 10x2 Sd 2,7 1000 1000 1000 600
1200 0,015 50-60 3-st. 10x6 So 2 1000 1000 1000 600
1200 0,015 50-60 3-st. 10x3 Sd 1 1000 1000 1000 600
1200 0,015 50-60 3-st. 10x2 Sd 0,7 1000 1000 1000 600

So = no self-locking; Ss = static self-locking; Sd = dynamic self-locking
1-stage = 3,9:1
2-stage = 15,2:1
3-stage = 59,3:1
* Brake required.
Duty cycle applies to 10 min. duty time.
For tensile loading, the maximum stroke force of the particular stroke speed applies.

 

DC 24 V DC

Motor
speed
 
[min-1]
Motor
power
 
[kW]
Duty
cycle
 
[%]
Planetary
gear
stages
Trapezoidal
thread
 
[mm]
Stroke
speed
 
[mm/s]
Maximum stroke force [N]
at stroke length [mm]
100 150 200 250
300
1600 0,055 25 1-st. 10x6 So 40* 450 450 450 450
2000 0,055 25 1-st. 10x3 Sd 25* 600 600 600 600
2000 0,055 25 1-st. 10x2 Sd 16* 600 600 600 600
2100 0,055 25 2-st. 10x6 So 14* 900 900 900 600
2300 0,055 50 2-st. 10x3 Sd 7,5 1000 1000 1000 600
2500 0,055 50 2-st. 10x2 Sd 5,5 1000 1000 1000 600
2600 0,055 50 3-st. 10x6 So 4,5 1000 1000 1000 600
2600 0,055 50 3-st. 10x3 Sd 2,2 1000 1000 1000 600
2600 0,055 50 3-st. 10x2 Sd 1,5 1000 1000 1000 600

So = no self-locking; Ss = static self-locking; Sd = dynamic self-locking
1-stage = 3,9:1
2-stage = 15,2:1
3-stage = 59,3:1
* Brake required.
Duty cycle applies to 10 min. duty time.
For tensile loading, the maximum stroke force of the particular stroke speed applies.

 

Technical Documentation