HOME
DOWNLOADS
TRADE FAIR
PRESS
CAREER

|
Mini 0 I Mini 01 I Mini 1 I Mini 2 I Mini 3 I Inquiry
Linear actuator Mini 01
Options I Power tables I Download Technical Documentation (PDF-file)
Standard Version:
Three-phase/AC, Stroke 100 mm, Transmission 1-stage, Fixing A
| |
Dimensions marked with * indicate the drive length of a standard drive (i.e. a stroke length of 100mm and a 1-stage or 1:1 transmission ratio). For longer stroke length and/or gear stages please add the corresponding dimensions x and y from the table below.
| Gear |
1:1 |
1-st. |
2-st. |
3-st. |
| x |
0 |
0 |
12 |
24 |
|
+ |
| Stroke length |
100 |
150 |
200 |
250 |
300 |
| y |
0 |
50 |
100 |
150 |
200 |
|
|
Fixing C
Fixing D, E, F
| |
| Standard |
| 100 mm stroke length |
| Mounting version A |
| Thermal protection |
| Splash-proof IP 54 |
| Integrated limit switches |
| Maintenance-free |
| Lifetime lubrication |
| 3-phase motor |
| Drive completely in stainless steel |
|
|
| Options |
| AC motors |
| Motors with special voltage upon request |
| 4 mounting versions |
| Special stroke length up to 300 mm |
| With force-dependent shut off |
| With adjustment ring |
| With adjustable rod end |
| With potentiometer |
| With encoder |
| With single disk spring-activated brake |
|
|
|
AC 3 x 230 / 400 V - 50 Hz
| |
Motor
speed
[min-1] |
Motor
power
[kW] |
Duty
cycle
[%] |
Planetary
gear
stages |
Trapezoidal
thread
[mm] |
Stroke
speed
[mm/s] |
Maximum stroke force [N]
at stroke length [mm] |
| 100 |
150 |
200 |
250
300 |
| 1300 |
0,05 |
15 |
1:1 |
10x6 So |
130* |
200 |
200 |
200 |
200 |
| 1300 |
0,05 |
15 |
1:1 |
10x3 Sd |
65* |
280 |
280 |
280 |
280 |
| 1300 |
0,05 |
15 |
1:1 |
10x2 Sd |
43* |
310 |
310 |
310 |
310 |
| 1300 |
0,05 |
15 |
1-st. |
10x6 So |
30* |
700 |
700 |
700 |
540 |
| 1300 |
0,05 |
15 |
1-st. |
10x3 Sd |
15 |
1000 |
1000 |
1000 |
540 |
| 1300 |
0,05 |
15 |
1-st. |
10x2 Sd |
10 |
1000 |
1000 |
1000 |
1000 |
| 1300 |
0,032 |
40 |
2-st. |
10x6 So |
7 |
1500 |
1500 |
1000 |
540 |
| 1300 |
0,032 |
40 |
2-st. |
10x3 Sd |
3 |
1500 |
1500 |
1000 |
540 |
| 1300 |
0,022 |
50-60 |
2-st. |
10x2 Sd |
2 |
1500 |
1500 |
1500 |
1000 |
| 1300 |
0,022 |
50-60 |
3-st. |
10x6 So |
1,5 |
1600 |
1600 |
1000 |
540 |
| 1300 |
0,022 |
50-60 |
3-st. |
10x3 Sd |
1 |
1600 |
1600 |
1000 |
540 |
| 1300 |
0,022 |
50-60 |
3-st. |
10x2 Sd |
0,5 |
1600 |
1600 |
1600 |
1000 |
So = no self-locking; Ss = static self-locking; Sd = dynamic self-locking
1-stage = 4,3:1
2-stage = 18,9:1
3-stage = 82,3:1
* For stroke speeds of 20 mm/sec. and above, a brake is required.
Duty cycle applies to 10 min. duty time.
For tensile loading, the maximum stroke force of the particular stroke speed applies.
The force and motor power stated at 40% and 60% will not change if the actuator is operated at 15% duty cycle.
|
AC 1 x 230 V - 50 Hz
| |
Motor
speed
[min-1] |
Motor
power
[kW] |
Duty
cycle
[%] |
Planetary
gear
stages |
Trapezoidal
thread
[mm] |
Stroke
speed
[mm/s] |
Maximum stroke force [N]
at stroke length [mm] |
| 100 |
150 |
200 |
250
300 |
| 1300 |
0,043 |
15 |
1:1 |
10x6 So |
130* |
120 |
120 |
120 |
120 |
| 1300 |
0,043 |
15 |
1:1 |
10x3 Sd |
65* |
170 |
170 |
170 |
170 |
| 1300 |
0,043 |
15 |
1:1 |
10x2 Sd |
43* |
190 |
190 |
190 |
190 |
| 1300 |
0,043 |
15 |
1-st. |
10x6 So |
30* |
420 |
420 |
420 |
420 |
| 1300 |
0,043 |
15 |
1-st. |
10x3 Sd |
15 |
600 |
600 |
600 |
540 |
| 1300 |
0,043 |
15 |
1-st. |
10x2 Sd |
10 |
600 |
600 |
600 |
600 |
| 1300 |
0,032 |
15/40 |
2-st. |
10x6 So |
7 |
1500/900 |
1500/900 |
1000/600 |
540 |
| 1300 |
0,032 |
15/40 |
2-st. |
10x3 Sd |
3 |
1500/900 |
1500/900 |
1000/600 |
540 |
| 1300 |
0,022 |
15/50-60 |
2-st. |
10x2 Sd |
2 |
1500/900 |
1500/900 |
1500/900 |
1000 |
| 1300 |
0,022 |
15/50-60 |
3-st. |
10x6 So |
1,5 |
1600/960 |
1600/960 |
1000/600 |
540 |
| 1300 |
0,022 |
15/50-60 |
3-st. |
10x3 Sd |
1 |
1600/960 |
1600/960 |
1000/600 |
540 |
| 1300 |
0,022 |
15/50-60 |
3-st. |
10x2 Sd |
0,5 |
1600/960 |
1600/960 |
1600/960 |
1000 |
So = no self-locking; Ss = static self-locking; Sd = dynamic self-locking
1-stage = 4,3:1
2-stage = 18,9:1
3-stage = 82,3:1
* For stroke speeds of 20 mm/sec. and above, a brake is required.
Duty cycle applies to 10 min. duty time.
For tensile loading, the maximum stroke force of the particular stroke speed applies.
Actuators with single phase motors reach only 60% of the force and motor power of those with 3-phase motors for the 15% duty cycle indicated.
The force and motor power stated at 40% and 60% will not change if the actuator is operated at 15% duty cycle.
|
Download Technical Documentation (PDF-file)
|