Deutsch  I  English  I  Français


Home
Downloads
News
Trade Fair
Press
Career
Imprint



Mini 0    I    Mini 01    I    Mini 1    I    Mini 2    I    Mini 3    I    Inquiry

Linear actuator Mini 01

Options    I    Power tables    I    Download Technical Documentation (PDF-file)

Standard Version:
Three-phase/AC, Stroke 100 mm, Transmission 1-stage, Fixing A



Dimensions marked with * indicate the drive length of a standard drive (i.e. a stroke length of 100mm and a 1-stage or 1:1 transmission ratio). For longer stroke length and/or gear stages please add the corresponding dimensions x and y from the table below.

Gear 1:1 1-st. 2-st. 3-st.
x 0 0 17 32
+
Stroke length 100 150 200 250 300
y 0 50 100 150 200

Fixing C

 

Fixing D, E, F

 

Standard Options
100 mm stroke length AC motors
Mounting version A Motors with special voltage upon request
Thermal protection 4 mounting versions
Splash-proof IP54 Special stroke length up to 300 mm
Integrated limit switches With force-dependent shut off
Maintenance-free With adjustment ring
Lifetime lubrication With adjustable rod end
3-phase motor With potentiometer
Drive completely in stainless steel With encoder
  With single disk spring-activated brake

 

AC 3 x 230 / 400 V - 50 Hz

Motor
speed
 
[min-1]
Motor
power
 
[kW]
Duty
cycle
 
[%]
Planetary
gear
stages
Trapezoidal
thread
 
[mm]
Stroke
speed
 
[mm/s]
Maximum stroke force [N]
at stroke length [mm]
100 150 200 250
300
1300 0,05 15 1:1 10x6 So 130* 200 200 200 200
1300 0,05 15 1:1 10x3 Sd 65* 280 280 280 280
1300 0,05 15 1:1 10x2 Sd 43* 310 310 310 310
1300 0,05 15 1-st. 10x6 So 30* 700 700 700 540
1300 0,05 15 1-st. 10x3 Sd 15 1000 1000 1000 540
1300 0,05 15 1-st. 10x2 Sd 10 1000 1000 1000 1000
1300 0,032 40 2-st. 10x6 So 7 1500 1500 1000 540
1300 0,032 40 2-st. 10x3 Sd 3 1500 1500 1000 540
1300 0,022 50-60 2-st. 10x2 Sd 2 1500 1500 1500 1000
1300 0,022 50-60 3-st. 10x6 So 1,5 1600 1600 1000 540
1300 0,022 50-60 3-st. 10x3 Sd 1 1600 1600 1000 540
1300 0,022 50-60 3-st. 10x2 Sd 0,5 1600 1600 1600 1000

So = no self-locking; Ss = static self-locking; Sd = dynamic self-locking
1-stage = 4,3:1
2-stage = 18,9:1
3-stage = 82,3:1
* For stroke speeds of 20 mm/sec. and above, a brake is required.
Duty cycle applies to 10 min. duty time.
For tensile loading, the maximum stroke force of the particular stroke speed applies.
The force and motor power stated at 40% and 60% will not change if the actuator is operated at 15% duty cycle.

 

AC 1 x 230 V - 50 Hz

Motor
speed
 
[min-1]
Motor
power
 
[kW]
Duty
cycle
 
[%]
Planetary
gear
stages
Trapezoidal
thread
 
[mm]
Stroke
speed
 
[mm/s]
Maximum stroke force [N]
at stroke length [mm]
100 150 200 250
300
1300 0,043 15 1:1 10x6 So 130* 120 120 120 120
1300 0,043 15 1:1 10x3 Sd 65* 170 170 170 170
1300 0,043 15 1:1 10x2 Sd 43* 190 190 190 190
1300 0,043 15 1-st. 10x6 So 30* 420 420 420 420
1300 0,043 15 1-st. 10x3 Sd 15 600 600 600 540
1300 0,043 15 1-st. 10x2 Sd 10 600 600 600 600
1300 0,032 15/40 2-st. 10x6 So 7 1500/900 1500/900 1000/600 540
1300 0,032 15/40 2-st. 10x3 Sd 3 1500/900 1500/900 1000/600 540
1300 0,022 15/50-60 2-st. 10x2 Sd 2 1500/900 1500/900 1500/900 1000
1300 0,022 15/50-60 3-st. 10x6 So 1,5 1600/960 1600/960 1000/600 540
1300 0,022 15/50-60 3-st. 10x3 Sd 1 1600/960 1600/960 1000/600 540
1300 0,022 15/50-60 3-st. 10x2 Sd 0,5 1600/960 1600/960 1600/960 1000

So = no self-locking; Ss = static self-locking; Sd = dynamic self-locking
1-stage = 4,3:1
2-stage = 18,9:1
3-stage = 82,3:1
* For stroke speeds of 20 mm/sec. and above, a brake is required.
Duty cycle applies to 10 min. duty time.
For tensile loading, the maximum stroke force of the particular stroke speed applies.
Actuators with single phase motors reach only 60% of the force and motor power of those with 3-phase motors for the 15% duty cycle indicated.
The force and motor power stated at 40% and 60% will not change if the actuator is operated at 15% duty cycle.

 

Technical Documentation