Linear actuator Mini 1

Options    I    Power tables    I    Download Technical Documentation (PDF-file)

Standard Version:
Three-phase/AC, Stroke 150 mm, Transmission 1-stage, Fixing A



Dimensions marked with * indicate the drive length of a standard drive (i.e. a stroke length of 100mm and a 1-stage transmission ratio). For longer stroke length and/or gear stages please add the corresponding dimensions x and y from the table below.

Gear 1:1 1-st. 2-st. 3-st.
x 0 0 20 40
+
Stroke length 150 200 250 300 350 400
y 0 50 100 150 200 250

Fixing C

 

Fixing D, E, F

 

Standard Options
100 mm stroke length AC motors
Mounting version A Motors with special voltage upon request
Thermal protection 4 mounting versions
Splash-proof IP54 Special stroke length up to 400 mm
Integrated limit switches With force-dependent shut off
Maintenance-free With adjustment ring
Lifetime lubrication With adjustable rod end
3-phase motor With potentiometer
Drive completely in stainless steel With encoder
  With single disk spring-activated brake

 

AC 3 x 230 / 400 V - 50 Hz

Motor
speed
 
min-1
Motor
power
 
kW
Duty
cycle
 
%
Planetary
gear
stages
Trapezoidal
thread
Stroke
speed
Maximum stroke force [N]
at stroke length [mm]
150 200 250
300
350
400
1360 0,18 15 1:1 12x6 So 136* 600 600 600 600
1360 0,18 15 1:1 12x3 Sd 68* 850 850 850 850
1360 0,18 15 1:1 12x2 Sd 45* 900 900 900 900
1360 0,18 15 1-st. 12x6 So 32* 2200 2200 1560 940
1360 0,18 15 1-st. 12x4 Ss 21* 2500 2500 2500 1640
1360 0,18 15 1-st. 12x3 Sd 16 2510 2510 1560 940
1360 0,18 15 1-st. 12x2 Sd 10,5 3300 3300 2740 1640
1360 0,11 40 2-st. 12x6 So 7 3500 3000 1560 940
1360 0,11 40 2-st. 12x4 Ss 5 3500 3500 2740 1640
1360 0,11 40 2-st. 12x2 Sd 2,5 3500 3500 2740 1640
1360 0,06 50-60 3-st. 12x4 Ss 1 3500 3500 2740 1640
1360 0,06 50-60 3-st. 12x2 Sd 0,5 3500 3500 2740 1640

So = no self-locking; Ss = static self-locking; Sd = dynamic self-locking
1-stage = 4,3:1
2-stage = 18,9:1
3-stage = 82,3:1
* For stroke speeds of 20 mm/sec. and above, a brake is required.
Duty cycle applies to 10 min. duty time.
For tensile loading, the maximum stroke force of the particular stroke speed applies.
The force and motor power stated at 40% and 60% will not change if the actuator is operated at 15% duty cycle.

 

AC 1 x 230 V - 50 Hz

Motor
speed
 
min-1
Motor
power
 
kW
Duty
cycle
 
%
Planetary
gear
stages
Trapezoidal
thread
Stroke
speed
Maximum stroke force [N]
at stroke length [mm]
150 200 250
300
350
400
1360 0,14 15 1:1 12x6 So 136* 360 360 360 360
1360 0,14 15 1:1 12x3 Sd 68* 500 500 500 500
1360 0,14 15 1:1 12x2 Sd 45* 540 540 540 540
1360 0,14 15 1-st. 12x6 So 32* 1300 1300 1300 940
1360 0,14 15 1-st. 12x4 Ss 21* 1500 1500 1500 1500
1360 0,14 15 1-st. 12x3 Sd 16 1500 1500 1500 940
1360 0,14 15 1-st. 12x2 Sd 10,5 2000 2000 2000 1640
1360 0,11 15/40 2-st. 12x6 So 7 3500/2100 3000/1800 1560/940 940
1360 0,11 15/40 2-st. 12x4 Ss 5 3500/2100 3500/2100 2740/1640 1640
1360 0,11 15/40 2-st. 12x2 Sd 2,5 3500/2100 3500/2100 2740/1640 1640
1360 0,05 15/50-60 3-st. 12x4 Ss 1 3500/2100 3500/2100 2740/1640 1640
1360 0,05 15/50-60 3-st. 12x2 Sd 0,5 3500/2100 3500/2100 2740/1640 1640

So = no self-locking; Ss = static self-locking; Sd = dynamic self-locking
1-stage = 4,3:1
2-stage = 18,9:1
3-stage = 82,3:1
* For stroke speeds of 20 mm/sec. and above, a brake is required.
Duty cycle applies to 10 min. duty time.