Home
Downloads
News
Trade Fair
Press
Career
Imprint
|
Mini 0 I Mini 01 I Mini 1 I Mini 2 I Mini 3 I Inquiry
Linear actuator Mini 2
Options I Power tables I Download Technical Documentation (PDF-file)
Standard Version:
Three-phase/AC, Stroke 175 mm, Transmission 1-stage, Fixing A
Dimensions marked with * indicate the drive length of a standard drive (i.e. a stroke length of 100mm and a 1-stage transmission ratio). For longer stroke length and/or gear stages please add the corresponding dimensions x and y from the table below.
| Gear |
1-st. |
2-st. |
3-st. |
| x |
0 |
24 |
48 |
| + |
| Stroke length |
175 |
250 |
300 |
| y |
0 |
75 |
125 |
|
|
Fixing C
Fixing D, E, F
| Standard |
Options |
| 175 mm stroke length |
Motors with special voltage upon request |
| Mounting version A |
4 mounting versions |
| Thermal protection |
Special stroke length up to 300 mm |
| Splash-proof IP54 |
With force-dependent shut off |
| Integrated limit switches |
With adjustment ring |
| Maintenance-free |
With adjustable rod end |
| Lifetime lubrication |
With potentiometer |
| 3-phase motor |
With encoder |
| |
With single disk spring-activated brake |
|
AC 3 x 230 / 400 V - 50 Hz
Motor
speed
[min-1] |
Motor
power
[kW] |
Duty
cycle
[%] |
Planetary
gear
stages |
Trapezoidal
thread
[mm] |
Stroke
speed
[mm/s] |
Maximum stroke force [N]
at stroke length [mm] |
| 175 |
250
300 |
| 1360 |
0,5 |
15 |
1-st. |
18x8 So |
49* |
3800 |
3800 |
| 1360 |
0,5 |
15 |
1-st. |
18x4 Ss |
24,5* |
5000 |
5000 |
| 1360 |
0,5 |
15 |
1-st. |
18x3 Sd |
18 |
5300 |
5300 |
| 1360 |
0,5 |
15 |
2-st. |
18x8 So |
13 |
10000 |
9080 |
| 1360 |
0,3 |
40 |
2-st. |
18x4 Ss |
6 |
10000 |
9080 |
| 1360 |
0,3 |
40 |
2-st. |
18x3 Sd |
5 |
10000 |
10000 |
| 1360 |
0,15 |
50-60 |
3-st. |
18x4 Ss |
2 |
14000 |
9080 |
| 1360 |
0,15 |
50-60 |
3-st. |
18x3 Sd |
1,5 |
14000 |
12000 |
So = no self-locking; Ss = static self-locking; Sd = dynamic self-locking
1-stage = 3,7:1
2-stage = 14,1:1
3-stage = 52,7:1
* For stroke speeds of 20 mm/sec. and above, a brake is required.
Duty cycle applies to 10 min. duty time.
For tensile loading, the maximum stroke force of the particular stroke speed applies.
|
Technical Documentation
|