Deutsch  I  English  I  Français


Home
Downloads
News
Trade Fair
Press
Career
Imprint



Mini 0    I    Mini 01    I    Mini 1    I    Mini 2    I    Mini 3    I    Inquiry

Linear actuator Mini 3

Options    I    Power tables    I    Download Technical Documentation (PDF-file)

Standard Version:
Three-phase/AC, Stroke 175 mm, Transmission 1-stage, Fixing A



Dimensions marked with * indicate the drive length of a standard drive (i.e. a stroke length of 100mm and a 1-stage transmission ratio). For longer stroke length and/or gear stages please add the corresponding dimensions x and y from the table below.

Gear 1-st. 2-st. 3-st.
x 0 35 70
+
Stroke length 175 250 300 350 400 450 500
y 0 75 125 175 225 275 325

Fixing C

 

Fixing D, E, F

 

Standard Options
175 mm stroke length Motors with special voltage upon request
Mounting version A 4 mounting versions
Thermal protection Special stroke length up to 500 mm
Splash-proof IP54 With adjustable rod end
Integrated limit switches With adjustment ring
Maintenance-free With single disk spring-activated brake
Lifetime lubrication With potentiometer
3-phase motor With encoder

 

AC 3 x 230 / 400 V - 50 Hz

Motor
speed
 
[min-1]
Motor
power
 
[kW]
Duty
cycle
 
[%]
Planetary
gear
stages
Trapezoidal
thread
 
[mm]
Stroke
speed
 
[mm/s]
Maximum stroke force [N]
at stroke length [mm]
175 250
300
350
400
450
500
1400 1,5 15 1-st. 28x8 Ss 47* 8100 8100 8100 8100
1400 1,5 15 1-st. 28x5 Sd 29* 8900 8900 8900 8900
1400 1,5 15 1-st. 28x3 Sd 17,5 9900 9900 9900 9900
1400 1,5 15 2-st. 28x8 Ss 12 20000 20000 19400 13120
1400 1,5 15 2-st. 28x5 Sd 7,3 20000 20000 20000 20000
1400 0,75 40 2-st. 28x3 Sd 4,4 20000 20000 20000 20000
1400 0,5 50-60 3-st. 28x8 Ss 2,9 26000 26000 19400 13120
1400 0,5 50-60 3-st. 28x5 Sd 1,8 26000 26000 26000 20000
1400 0,5 50-60 3-st. 28x3 Sd 1,1 26000 26000 26000 26000

So = no self-locking; Ss = static self-locking; Sd = dynamic self-locking
1-stage = 4:1
2-stage = 16:1
3-stage = 64:1
* For stroke speeds of 20 mm/sec. and above, a brake is required.
Duty cycle applies to 10 min. duty time.
For tensile loading, the maximum stroke force of the particular stroke speed applies.

 

Download Technical Documentation (PDF-file)